Valves

Kuterlite

Brass lockshield gate valve, copper x copper, to BS 5154/B, PN16

Brass lockshield gate valve, copper x copper, to BS 5154/B, PN16

Key Features

  • Copper x Copper To BS 5154/B
SizePattern No.Pack 1 QtyPack 2 QtyCodeBarcodePrice (£) each ex VAT
15mmK416LS505022050616951£44.02
22mmK416LS505022050616968£51.92
28mmK416LS205022050616975£94.10
CodeDescriptionAB
61695 63660.18
61696 74720.37
61697 79810.68
Pegler Yorkshire reserve the right to change specifications
SizePattern No.CodeIndividual Weight (kg)Pack 1 Weight (kg)Pack 2 Weight (kg)
15mmK416LS616950.201.070.00
22mmK416LS616960.321.660.00
28mmK416LS616970.440.920.00
SizePattern No.CodeKv m3/h
15mmK416LS6169514.00
22mmK416LS6169632.00
28mmK416LS6169757.00
Pegler Yorkshire reserve the right to change specifications

Pegler Yorkshire Kuterlite Guarantee - Terms and Conditions

Products are subject to a guarantee that is between Pegler Yorkshire and the final purchaser of the product. When correctly assembled with the stated tubes and pipe the length of guarantee is as follows:

Kuterlite fittings and valves installed with specified tubes and pipes with the exception of those listed below - 25 years.

Kuterlite Flexifit flexible connectors - 10 years

Kuterlite 600/900 fittings and valves installed with XPress Carbon Steel System tube in sizes up to 28mm - 10 years

Kuterlite 600/900 fittings and valves installed with other manufacturers carbon steel tube to DIN 2394/NEN 1982 in sizes up to 28mm - 5 years

The guarantee is subject to proof of purchase being supplied.

This guarantee does not affect any statutory rights the consumer may have in law.

The guarantee covers manufacturing or material defects when installed in accordance with our instructions on specified tube materials and applications, and does not cover parts subject to normal wear and tear.

This product range has been designed for the use of homeowners, domestic and commercial applications and therefore the Guarantee is subject to the product being properly selected for their intended service conditions.

The guarantee is not applicable where the product is fitted contrary to the conditions in the fitting instructions.

This is reinforced where valves are covered by the European Pressure Equipment Directive (PED97/23/EC) where Installation, Operating and Maintenance Instructions are supplied with each product and/or carton.

Provided it is installed correctly and receives adequate preventative maintenance it should give years of trouble–free service.

Abusive behaviour and accidental damage to the product are not covered by this guarantee.

The extent of this liability is limited to the cost of the replacement of the defective item and not to installation or consequential damages.

SizePattern No.CodeBSi Kitemark License
15mmK416LS61695approved by BSi Kitemark License
22mmK416LS61696approved by BSi Kitemark License
28mmK416LS61697approved by BSi Kitemark License
DescriptionMinimum Operating
Pressure (bar)
Maximum Cold Working
Pressure (bar)
Maximum Hot
Working Pressure (bar)
K416LS Gate valveNo Minimum Operating Pressure16.0 bar at temperatures up to 30oC5.0 bar at temperatures up to 120oC

Care
No regular aesthetic care is required for this product

Maintenance
A regular maintenance program is the most efficient method of ensuring longer term operational efficiency of the selected valve. Such a program would need to include a risk assessment and a planned procedure of how the maintenance will be carried out. The possibility of operational limits being exceeded and the potential hazards ensuring must be considered as part of this assessment. This should be implemented to include visual checks on the valve’s condition and any development of unforeseen conditions, which could lead to failure. The correct fitting tools and equipment should be used for valve maintenance work. Separate means of draining the pipe work must be provided when carrying out any maintenance to valves. Where there may be any system debris this could be collected and /or filtered by installation of the appropriate protective device.

For further help please contact your local engineer.

If your product is under warranty please contact the Service Support Team on: 0800 1560050

Included in your data sheet will be: (Please uncheck the details not required)

General Information

Dimensions

Flow Data

Guarantee / Warranty

Approvals

Pressure & Temperature

Care & Maintenance

Installation Instructions

© 2019 Pegler. All Rights Reserved. Site Map  Social Media
Registered office: Pegler Yorkshire Group Ltd, St Catherine's Ave, Doncaster, S Yorkshire, DN4 8DF Company no : 00401507
Legal: Privacy Policy  Cookie Policy  Modern Slavery Statement   Equal Opportunities  Terms & Conditions

PY Blog RSS twitter facebook link in youtube
Aalberts Industries