Code | Description | A |
---|---|---|
634006 | ETP CP TERRIER EXTENSION TAIL PIECE | 40 |
Size | Pattern No. | Code | Individual Weight (kg) | Pack 1 Weight (kg) | Pack 2 Weight (kg) |
---|---|---|---|---|---|
40mm | Extension Tail Piece CP | 634006 | 0.07 | 0.70 | 0.00 |
Thermostatic and Manual Radiator Valves
Pegler Customcare 5 Year Guarantee - Terms & Conditions
Products are subject to a 5 year guarantee that is between Pegler and the final purchaser of the product.
The guarantee is subject to proof of purchase being supplied.
This guarantee does not affect any statutory rights the consumer may have in law.
The guarantee covers manufacturing or material defects and is not applicable where the product is fitted contrary to conditions of use in our literature.
The guarantee is subject to the following limitations:
1. The valves are designed for use only in an indirect open-vented or sealed water-filled central heating and/or indirect hot water system and for no other purpose.
2. They must be used within the pressure and temperature limits stated in the technical information table below.
Operating Conditions (Maximum)
System Water Temperature (at 5bar) : 120 °C
Operating pressure (at 65 oC) :10 bar
3. Under no circumstances must they be used to in systems containing liquids or solutions other than water. The only exception is the addition of a proprietary central heating corrosion inhibitor, cleaner or anti-freeze to the system water in accordance with the manufacturer’s instructions.
4. Damage caused by abusive behaviour and accidental damage to the product are not covered by this guarantee
The extent of Pegler liability is limited to the cost of the replacement of the defective item and not to fitting or consequential damages.
Description | Minimum Operating Pressure (bar) | Maximum Cold Working Pressure (bar) | Maximum Hot Working Pressure (bar) |
---|---|---|---|
Extension Tail Piece | No Minimum Operating Pressure | 10.0 bar at temperatures up to 120oC | Not Suitable for Maximum Hot Working Pressure |
Care
No regular aesthetic care is required for this product
Maintenance
No regular maintenance is required for this product.
For any further help please contact the Service Support Team on: 0800 1560050.
Regulations
Terrier manual radiator valves are generally designed to BS2767-10.
For valves with compression connections, the connections are designed to BS EN1254-2; threaded connections comply with BS 21 or BS 2779.
They are designed for use only in an indirect open-vented or sealed water-filled central heating and/or indirect hot water system and for no other purpose.
They must be used within the pressure and temperature limits stated in the technical information table below.
Operating Conditions | Maximum |
System Water Temperature (at 5bar) | 120°C |
Operating pressure (at 65°C) | 10 bar |
Under no circumstances must they be used in systems containing liquids or solutions other than water. The only exception is the addition of a proprietary central heating corrosion inhibitor, cleaner or anti-freeze to the system water in accordance with the manufacturer's instructions.
Terrier heating controls are manufactured to a strict quality assurance system in accordance with ISO 9000: 2001
Included in your data sheet will be: (Please uncheck the details not required)
General Information
Dimensions
Guarantee / Warranty
Pressure & Temperature
Care & Maintenance
Regulations